OPC-UA Writer

Write a value to a PLC node via OPC-UA protocol.

The OPC-UA Writer module writes a value from the pipeline data registry to a PLC node. This is commonly used to send inspection results (pass/fail), compliance scores or other calculated values back to the PLC.

OPC-UA Writer module in the action plan editor

Configuration

Field Type Description
plc_name string The label of the PLC connection (configured on the Devices → PLC page)
plc_node string The OPC UA node address, entered manually or selected with Browse
value string The data registry key whose value should be written (e.g., anomaly_0.pred_score)

The value field is not a literal value — it is a reference to a key in the data registry. The module reads the actual value from the registry at runtime and writes it to the PLC.

Behavior

  1. Reads the referenced value from the data registry.
  2. Connects to the specified PLC.
  3. Writes the value to the specified node.

Inputs & Outputs

Direction Key Type Description
Input <value> (registry key reference) varies The value to write, read from the registry
Output — — No data output (only execution time is recorded)

Configure the PLC connection first. Browse requires the selected PLC to be reachable; an invalid or unavailable node produces an execution error.